(b) Inspect the No. 1 vacuum switching valve assembly operation.
(1) Check that air does not flow from ports.
(2) Apply battery voltage across the terminals.
(3) Check that air flows from ports.
If operation is not as specified, replace the No. 1 vacuum switching valve assembly.
|